Description
Giropes L6G Single Point Load Cell
Features
- Single Point load cell.
- Anodised aluminium construction, silicone sealing.
- 3000 divisions OIML R60 class C.
- Protection IP65.
- High accuracy with off-centre loads.
Specifications
- Nominal capacities (Ln) 100-200-500 kg
- Accuracy class C3
- Output sensitivity 2.0 ± 0.2 mV/V
- Maximum capacity 100-200-500 kg
- Max number of load cell intervals 3000
- Minimum dead load 0
- Safe overload 150 % Emax
- Excitation recommended 5 – 12 V
- Excitation maximum 18 V
- Zero balance ≤±2 % RO
- Input impedance 409±6 Ω
- Output resistance 350±3 Ω
- Insulation impedance ≥5000 MΩ
- Temperature range compensated -10 – +40 ºC
- Temperature range operating -35 – +65 ºC
- Atmospheric protection IP65
- Maximum dimension for the platform 600×600 mm²
- Cable length 5 m