Description
Main Features
- C6 Precision Class
- Off Centre Load Compensated
- Aluminium Alloy Construction
- IP67 Protection
- Maximum Capacities from 7kg to 36kg
- For Platforms with Dimensions up to 450mm x 450 mm
- Shielded Connection Cable
- OIML Certificate Available on Request
- Test Certificate Available on Request
Technical Features
- Minimum load cell verification interval: Vmin = EMax / 14.000-25.000
- Maximum number of verification intervals: nLC = 6000
- Sensitivity: 2mV/V ± 10%
- Temperature effect on zero:
from ±0,0056% F.S./10K to ±0,01% F.S/10K - Temperature effect on Full Span:
0,0058% F.S./10K (-10°C/+20°C) 0,087% F.S./10K (+20°C/+40°C) - Compensated Temperature Range: -10°C/+40°C
- Operating Temperature Range: -10°C/+50°C
- Maximum excitation voltage without damage: 15 Vdc
- Input Resistance: 300..500 Ohm
- Output Resistance: 300..500 Ohm
- Zero Balance: 0 ±0,1mV/V (at 100V)
- Insulation Resistance: >2000 MOhm
- Mechanical limit load in service: 150% F.S.
- Destructive load: 300% F.S.
- Deflection at nominal load <0,5mm
- 6-wire shielded cable, 3m long, 4,7mm diameter
ATEX Version
- The CCATEX certificate makes the load cell suitable for use in hazardous areas with protection methods according to:
ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga
ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65.
The certificate includes the manual and the ATEX CE conformity declaration (available in EN, DE, FR, and IT). - IMPORTANT: the certificate refers to the single load cell. For systems with more load cells, it is necessary to order one certificate for each load cell.
Please click here for the Dini Argeo SPG C6 single point load cell datasheet …..