Description
MAIN FEATURES
- C3 PRECISION CLASS
- NICKEL-PLATED CONSTRUCTION
- POTTED SEAL, IP67 PROTECTION
- MAX. CAPACITIES FROM 500 TO 2000 kg
- SHIELDED CONNECTION CABLE
- TEST CERTIFICATE AVAILABLE UPON REQUEST
TECHNICAL FEATURES
- Minimum load cell verification interval Vmin = EMax / 10.000
- Maximum number of verification intervals nLC = 3000
- Combined error 0,017% of Full Scale Output (F.S.)
- Non linearity ± 0.02% FS
- Hysteresis ± 0.02% FS
- Repeatability ± 0.01% FS
- Full Scale Output 2mV/V ± 0.5%
- Zero balance ± 1% FS
- Compensated Temperature Range -10°C/+50°C.
- Operating Temperature Range -20°C/+60°C.
- Creep error after 30 minutes <0,02% F.S.
- Maximum tolerated excitation voltage 15 Vdc
- Input Resistance 380 ± 20 Ohm
- Output Resistance 350 ± 5 Ohm
- Insulation Resistance >5000 MOhm
- Safe Overload 150% F.S.
- Ultimate Overload 300% F.S.
- 6-wire shielded cable, 3.5m long, 5 mm diameter
ATEX VERSION
The CCATEX certificate makes the load cell suitable for use in hazardous areas with protection methods according to:ATEX II 3G Ex ic IIC T6 (Ta -20÷+65°C) Gc
ATEX II 3G Ex nA IIC T6 (Ta -20÷+65°C) Gc
ATEX II 3D Ex tc IIIC T85°C (Ta -20÷+65°C) Dc IP65.
The certificate includes the manual and the ATEX CE conformity declaration (available in EN, DE, FR, and IT).
IMPORTANT: the certificate refers to the single load cell. For systems with more load cells, it is necessary to order one certificate for each load cell.
Please click here for the SBT Nickel Plated Shear Beam Load Cell Datasheet …..